• Structural Steel Construction
- Floor and roof framing four side are WF beam 12X14W Th channel
6x8.2 cross bridging as required
- Main support columns 3x3x7 ga square tube
- All welding AWS Certified
• Floor and Roof Substruction
- 20ga G90 B deck
- Single layer non-structural, fiberglass-faced silicone-treated
gypsum core panel sheathing-floor.
- Double layer non-structural, fiberglass-faced silicone-treated
gypsum core panel sheathing-roof.
• Wall Framing
- All interior and exterior wall are full 4"x16ga metal
stud framing.
- All construction joints are mechanically fastened and welded.
• Exterior Doors
- 3'0" x 6'8" 18ga hollow core metal door
- 16ga metal door frame
- One touch panic device with lever key exterior
- Door closer
• Windows (150mph wnidload to meet or exceed
state and local standards)
- CWS Service 7000
• Roof Hatch
- Bilco S 50 aluminum hatch 2'6" x3'0"
- Aluminum access ladder with aluminum Tread Brite wall protection.
• Finish Roof
- Hydro stop premium coat system entire deck
- Hydro stop barrier guard system on camera deck
- 42" aluminum pickett guard rails as camera deck 4 sides
- Four gang GFI receptacles in weatherproof box with cover
|
• Electrical
- GE 100A load center with 100A main breaker
- 3# 2 copper leads with #3 copper ground incased in liquid title
pig tail.
- GE 1p 20A 120V CB breakers
- GE 2p 120/240V CB beakers
- Hubwell 20A Rect and switches
- Hubwell 20A GFCL devices.
- All circuits are 12/2 with green ground, aluminum MC cable.
- All work boxes and fixtures are grounded.
- Emergency Lighting
- Lith GELMZp 2 head light
- Lith ELANXH0806 remote head
- Lith LQMSW3R lighted exit
- Florescent lighting
- Metalux 4 lamp 4" wrap around #0605121020
- 1800 BTU wall mount A/C unit with heat strip
• Exterior Finish
- 26ga R panel 1 1/4" rib
- 26ga trim and flashing features to meet 150 mph windload
- Vertical screw pattern (+ -) 20" - 150 mph windload
- Horizontal screw pattern both sides of ribs horizontally
• Interior Finish and Trim
- All floors, wall and ceiling are insulated. R11 fiberglass battery
minimum
- Wall panels, 1/2" Dursan vinyl clad 4x8 panels with concealed
fastners (no exposed fastners) all inside and outside corners
trimmed with aluminum angle
- Floor finish - aluminum Tread Brite with aluminum tread return
under counter top.
- Black vinyl cove base. All walls except Tread Brite return
- Ceilings - Armstrong 7300 series 244 white Prelude grid system
with Armstrong vinyl faced fiberglass lay in panels, L-2x4x5/8"
- Counter top shall be stainless steel construction (no wood or
wood products)
|